ICM255 Fan Blower Control - Dual On/Off Delay Timer (Fixed Time Delay)
Controls the circulating fan in heat pump, air conditioning and forced air systems. Delay on make lets air reach proper level prior to turning on the fan. Off delay timing function continues to run the fan at the end of the heating/cooling cycle, thereby purging ducts of residual air and increasing system efficiency.
ICM270 Fan Blower Control, Direct OEM Replacement - Dual On/Off Delay Timer
ICM offers low cost, direct wire for wire replacement fan blower controls for many popular OEM models. The fan blower controls monitors safety switches, provides on and off delays and controls the speed of the fan in heat pumps, air conditioners and forced air systems according to the logic of the original board.
Product Features
•Dual function fan delay timer
•Controls the circulating fan in heat pump, A/C and forced air systems
•OFF delay purges ducts of residual air
•ON delay allows air to reach the proper comfort level prior to energizing the fan
ICM Controls
Furnace Control Control - replacement for Nordyne 903106-Kit control boards for use with G3, G4, G5, G6, M2 and M3 furnace modules
ICM282A
ICM282A • Low cost replacement for Carrier HK42FZ004/007/008/009/011/013/016
icm2902 ICM Controls IPI Gas Ignition Control
Specification Control Voltage: Line 24V (18-30 VAC), 50/60Hz Anticipator Setting: 0.3A plus valve load @ 24VAC Prepurge: 15 seconds Trial for Ignition: 85 seconds Lockout: 60 minutes Flame Failure Response Time: 2 seconds LED: See product label for error codes Patents: - #6,222,719: Ignition Boost - #5,917,691: Fail Safe Relay Driver - #5,889,645: Energy Preservation and Transfer Mechanism - #5,930,104: PWM Relay Actuator Circuit
Furnace Control Control - replacement for Carrier LH33WP003/3A control boards
Control Voltage: 24 VAC (18-30 VAC), 60Hz Line Voltage: 208/230 VAC, 60Hz Timing: - Pre-Purge: 45 seconds - Trial for Ignition: 5+2 seconds - Retry Period: Every 20 seconds for 15 minutes - Lockout: Manual reset - Post-Purge: 45 seconds LED Indicators: - Red LED: Steady ON-normal operation; Flashing-fault codes Inputs: - Power: RT and C - Thermostat Interface: R,W, and G - Safety Switches: RS, LS, and CS - Combustion Motor Hall Effect Sensor Flame Sensing Outputs: - Spark - Gas Valve: GV - Combustion Motor: CM - Blower Motor: BM - Indoor Fan Motor: IFO
ICM276 Fan Blower Control, Direct OEM Replacement - Dual On/Off Delay Timer
ICM offers low cost, direct wire for wire replacement fan blower controls for many popular OEM models. The fan blower controls monitors safety switches, provides on and off delays and controls the speed of the fan in heat pumps, air conditioners and forced air systems according to the logic of the original board.
Product Features
•Microprocessor-based fan blower
•Inducer fan outputs
•Controls the circulation fan in gas/heat and A/C ssytems
•OFF delay purges ducts of residual air